PRODUCTS - Commercial Steam Unit
Installation For 1 Room


COMMERCIAL STEAM GENERATOR EXECUTIVE SERIES (ES) WITH AUTO POWER FLUSH


INTRODUCTION TO STEAM GENERATOR FUNCTIONS

This unit is designed and manufactured based on your specific requirements. Each steam generator has it own function, which may operate differently from another steam generator. This section explains different functions on steam generators. Your unit may have some of these functions. Read your order sheet to find out which functions your unit has.

REGULAR 2-in-1 SYSTEM
The unit has two heating stages. When the thermostat is calling for heat, both stages get engaged and produce strong steam until the temperature SETPOINT is reached in the steam room. Then one stage, which is controlled by thermostat, goes off and the other stage keeps on producing steam (steady but slow).

SPECIAL 2-in-1 SYSTEM
This system also has two stages, but a separate thermostat controls each stage individually. The SETPOINT for the top thermostat is slightly higher than the bottom thermostat. When the lower SETPOINT in bottom thermostat is reached, one stage goes off, but the other stage keeps on steaming until the higher SETPOINT in top thermostat is reached.

STAND BY SYSTEM
The unit only produces steam on demand. When the user turns on the 30 minute mechanical or IN-ROOM-TOUCH timer the unit start producing strong steam until one of the following happens:

    • Timer times out (turns off)
    • Temperature SETPOINT is reached
Then the unit stops producing steam and stands by for the next request. Only the first heating cycle in the daily schedule will take about 10 minutes longer than the consequent next cycles to produce steam.

BINARY SETTING
The thermostat implements two different sets of SETPOINTS to control the temperature in the steam room. The regular SETPOINT is about 117°F (47°C) and the secondary SETPOINT is less than by OFFSET value, 25°F (15°C):
        Secondary SETPOINT= Regular SETPOINT – OFFSET Value
        Secondary SETPOINT= 117°F – 25°F= 92°F
A mechanical timer or Electronic In-Room- Touch timer activates the transition from Regular SETPOINT to Secondary SETPOINT and vice versa.



 
The most advanced Steam Generators and Saunas
© 2003 Steam-Sauna.com Hardwood Flooring