PRODUCTS - Residential Steam Unit
Installation


BLUE DESIGN CONTROLLER Installation, Operation and Set up

A. Installation
Install the controller outside the steam room and preferably beside the door where you can have easy access. Run the sensor wire to the steam room. The best location for sensor is 5” above the door and the sensor tip should be exposed 1.5” into the room. Plug in the connector cable. The arrow on the male and female plugs should face each other.

Note: The controller is provided with a standard length of 12 ft connector cable and 13 ft sensor cable. If you need to extend them up to 50 ft, use RG3 or RG5 cables or 2 pairs cable (22 to 18 AWG).

B. Operation
The controller performs 4 functions:
     1. ON/ OFF: Turns ON or OFF the steam generator at any desired time.
     2. Time control: Controls the duration of steam generator operation, which can be set from 1 to 99 minutes. The unit
        will produce steam until it times out.
     3. Temperature control: Controls the temperature setpoint in steam room, which can be set from 0°C to 75°C (32°F to
        167°F)
     4. Temperature display: Displays the current temperature of the steam room in Celsius or Fahrenheit. The
        temperature reading on the display can be changed from Celsius to Fahrenheit and vice versa.

Note: By default the temperature is programmed at 47°C (117°F), and the time is programmed at 30 minutes. The controller will keep the user programmed values until the power to the controller is lost. After power is restored it goes back to its original defaults.

C. Set up
     1. To turn the controller ON or OFF: Press and release the ON/OFF button once.
     2. To set the desired time: Press and release time or time button while the controller is ON, until the display
        shows your desired time. After 5 seconds the display switches back to the current temperature in the steam room.
     3. To set the desired temperature: Press and release the temp. or the temp. button while the controller is ON,
        until the display shows the desired temperature. After 5 seconds the display switches back to the current temperature
        in the steam room.
     4. To switch the display reading between Celsius and Fahrenheit: Turn off the controller first, then press and hold
        temp. button for 5 seconds and the LED light should switch from °C to °F and vice versa.

WARNING
Use this steam unit as the factory set it up. Modify it only on recommendation from the manufacturer. NEVER add valves or other controls to the steam line. To do so may cause equipment failure or personal injury. If control devices other than those approved by the manufacturer are added to the steam line, the warranty will be null and void.

For all models, please note the following steps:

A. When you need to shut down the power –
   1. Turn off the unit at the timer;
   2. Wait for 15-30 seconds;
   3. Shut down the main power supply.

Failure to do this may cause the microprocessor to malfunction.

   Exceptions: Power failures or emergency.
   If the unit has lost power and is not operating correctly, follow the shut down procedure but leave the power turned off for
   a minimum of 10 min. This will allow overcharged capacitors to drain off excess charge.

B. To start it again -
   1. Turn on the power at the panel;
   2. Then turn on the timer.



 
The most advanced Steam Generators and Saunas
© 2003 Steam-Sauna.com Hardwood Flooring